Laser Power & Energy Sensors, for PEM-TS-4.3 Stand-alone Controller

PM-RS

Laser Power & Energy Sensors, for PEM-TS-4.3 Stand-alone Controller
In stock
SKU
PM-RS
The OptoSigma® Stand-Alone Power Meter sensors operate with the PEM-TS-4.3 handheld control console which is powered by a rechargeable lithium battery for 15-hour run time. Stand-Alone Power Meters offer a configurable analogue output, easy data logging and can also be connected to a PC via its USB port. The sensor heads are composed of the thermopile detector, housing, and cable with DB15 connector termination.
custom product
Customize product
Name Energy Range Power Range Wavelength Range Aperture Delivery Price Add to cart
i
10W High-Energy-Density Thermal Sensor, 160 kW/sqcm, 10 mJ - 15 J, 12-mm Sensor Aperture, Broadband, used with PEM-TS-4.3 Stand-alone Controller
PM10-12D-DF
10 mJ - 15 J 10 mW - 10 W 0.2 - 2.1µm 12mm
1-3 weeks
-
Cooling Convection
Max Intermitent Power 15W
Power Resolution 100uW
Noise Equivalent Power (NEP) 600uW
Response Time (0-90%) 1s
Power Calibration Uncertainty +/-3%
Power Linearity +/-1%
Energy Resolution 0.1mJ
Energy Calibration Uncertainty +/-5%
Type of Absorber DIF
Maximum Power Density 160kW/cm2
Max Energy Density 5ms pulse width: 1200 J/cm2, 10us pulse width: 22 J/cm2, 10ns pulse width: 6.5 J/cm2
Interface DB15 Conector, Compatible with PEM-TS-4.3 Controller
i
2W Broadband Thermal Sensor, 1mJ - 2J, 10-mm Sensor Aperture, used with PEM-TS-4.3 Stand-alone Controller
PM2-12D-HP
1 mJ - 2 J 1 mW - 2 W 0.19 - 25µm 10mm
1-3 weeks
-
Cooling Convection
Max Intermittent Power 2W
Power Resolution 10uW
Noise Equivalent Power (NEP) 50uW
Response Time (0-90%) 2.5s
Power Calibration Uncertainty +/-3%
Power Linearity +/-1%
Energy Resolution 10uJ
Energy Calibration Uncertainty +/-5%
Type of Absorber HPB
Maximum Power Density 18kW/cm2
Max Energy Density 5ms pulse width: 36 J/cm2, 10us pulse width: 1.2 J/cm2, 10ns pulse width: 0.3 J/cm2
Interface DB15 Conector, Compatible with PEM-TS-4.3 Controller
i
30W Broadband Thermal Sensor, 50 mJ - 45 J, 25-mm Sensor Aperture, used with PEM-TS-4.3 Stand-alone Controller
PM25-25D-HP
50 mJ - 45 J 20 mW - 30 W 0.19 - 11µm 25mm
1-3 weeks
-
Cooling Convection
Max Intermittent Power 45W
Power Resolution 1mW
Noise Equivalent Power (NEP) 1mW
Response Time (0-90%) 1.5s
Power Calibration Uncertainty +/-3%
Power Linearity +/-1%
Energy Resolution 1mJ
Energy Calibration Uncertainty +/-5%
Type of Absorber HPB
Maximum Power Density 18kW/cm2
Max Energy Density 5ms pulse width: 36 J/cm2, 10us pulse width: 1.2 J/cm2, 10ns pulse width: 0.3 J/cm2
Interface DB15 Conector, Compatible with PEM-TS-4.3 Controller
i
200W Broadband Thermal Sensor, 200 mJ - 200 J, 25-mm Sensor Aperture, used with PEM-TS-4.3 Stand-alone Controller
PM200-25D-HP
200 mJ - 200 J 150 mW - 200W 0.19 - 11µm 25mm
1-3 weeks
-
Cooling Forced Air with Fan
Max Intermitent Power 250W
Power Resolution 10mW
Noise Equivalent Power (NEP) 10mW
Response Time (0-90%) 1.7s
Power Calibration Uncertainty +/-3%
Power Linearity +/-1%
Energy Resolution 10mJ
Energy Calibration Uncertainty +/-5%
Type of Absorber HPB
Maximum Power Density 4kW/cm2
Max Energy Density 5ms pulse width: 36 J/cm2, 10us pulse width: 1.2 J/cm2, 10ns pulse width: 0.3 J/cm2
Interface DB15 Conector, Compatible with PEM-TS-4.3 Controller
i
5W Broadband Thermal Sensor, 10 mJ - 5 J, 10-mm Sensor Aperture, used with PEM-TS-4.3 Stand-alone Controller
PM5-12D-BB
10 mJ - 5 J 10 mW - 5 W 0.19 - 25µm 10mm
1-3 weeks
-
Cooling Convection
Max intermittent Power 45W
Power Resolution 100uW
Noise Equivalent Power (NEP) 500uW
Response Time (0-90%) 0.7s
Power Calibration Uncertainty +/-3%
Power Linearity +/-1%
Energy Resolution 0.1mJ
Energy Calibration Uncertainty +/-5%
Type of Absorber BBF
Maximum Power Density 200W/cm2
Max Energy Density 5ms pulse width: 3.6 J/cm2, 10us pulse width: 0.2 J/cm2, 10ns pulse width: 0.1 J/cm2
Interface DB15 Conector, Compatible with PEM-TS-4.3 Controller
i
10W Single-Pulse Laser Thermal Sensor, 50 mJ - 10 J, 25-mm Sensor Aperture, Broadband, used with PEM-TS-4.3 Stand-alone Controller
PL10-VA-25D
50 mJ - 10 J 2 mW - 10 W 0.4 - 5.2µm 25mm
1-3 weeks
-
Cooling Convection
Max Intermitent Power 15W
Power Resolution 100uW
Noise Equivalent Power (NEP) 100uW
Response Time (0-90%) 3s
Power Calibration Uncertainty +/-3%
Power Linearity +/-1%
Energy Resolution 0.1mJ
Energy Calibration Uncertainty +/-5%
Type of Absorber BB
Maximum Power Density 35W/cm2
Max Energy Density 10ms pulse width: 13 J/cm2, <10us pulse width: 10 J/cm2
Interface DB15 Conector, Compatible with PEM-TS-4.3 Controller
i
10W Broadband Thermal Sensor, 10 mJ - 15 J, 20-mm Sensor Aperture, used with PEM-TS-4.3 Stand-alone Controller
PM10-20D-HP
10 mJ - 15 J 10 mW - 10 W 0.19 - 11µm 12mm
1-3 weeks
-
Cooling Convection
Max Intermittent Power 15W
Power Resolution 100uW
Noise Equivalent Power (NEP) 600uW
Response Time (0-90%) 1s
Power Calibration Uncertainty +/-3%
Power Linearity +/-1%
Energy Resolution 0.1mJ
Energy Calibration Uncertainty +/-5%
Type of Absorber HPB
Maximum Power Density 18kW/cm2
Max Energy Density 5ms pulse width: 36 J/cm2, 10us pulse width: 1.2 J/cm2, 10ns pulse width: 0.3 J/cm2
Interface DB15 Conector, Compatible with PEM-TS-4.3 Controller
i
40W Broadband Thermal Sensor, 50 mJ - 60 J, 25-mm Sensor Aperture, used with PEM-TS-4.3 Stand-alone Controller
PM40-25D-HP
50 mJ - 60 J 20 mW - 40 W 0.19 - 11µm 25mm
1-3 weeks
-
Cooling Convection
Max Intermittent Power 60W
Power Resolution 1mW
Noise Equivalent Power (NEP) 1mW
Response Time (0-90%) 1.5s
Power Calibration Uncertainty +/-3%
Power Linearity +/-1%
Energy Resolution 1mJ
Energy Calibration Uncertainty +/-5%
Type of Absorber HPB
Maximum Power Density 9kW/cm2
Max Energy Density 5ms pulse width: 36 J/cm2, 10us pulse width: 1.2 J/cm2, 10ns pulse width: 0.3 J/cm2
Interface DB15 Conector, Compatible with PEM-TS-4.3 Controller
i
0.2W Broadband Thermal Sensor, 1 - 200 mJ, 10-mm Sensor Aperture, used with PEM-TS-4.3 Stand-alone Controller
A-02-D12-BBF
1 mJ - 200 mJ 0.1 mW - 200 mW 0.19 - 25µm 10mm
1-3 weeks
-
Cooling Convection
Max Intermittent Power 200mW
Power Resolution 10uW
Noise Equivalent Power (NEP) 5uW
Response Time (0-90%) 2s
Power Calibration Uncertainty +/-3%
Power Linearity +/-1%
Energy Resolution 10uJ
Energy Calibration Uncertainty +/-5%
Type of Absorber HPB
Maximum Power Density 200W/cm2
Max Energy Density 5ms pulse width: 3.6 J/cm2, 10us pulse width: 0.2 J/cm2, 10ns pulse width: 0.1 J/cm2
Interface DB15 Conector, Compatible with PEM-TS-4.3 Controller